This series of signal filters are used for control lines.
This series of signal filters are used for telephone, data communication, control and fire alarm.
All WEMC signal line filters are tested under the following standards and meet or exceed the performance and safety criteria defined by these standards:
Mil-F-15733
Mil-Std-220C
CISPR17:2011
UL1283
LVD 2014/35/EU
Type | Rated voltage | Rated current | Outline drawing | Band pass | Typical applications |
SF-T2 | 250VDC | 2x0.3A | 1 | 0-20kHz | Telephone, fax and AC/DC switch signal |
SF210-1 | 250VAC | 2x1A | 1 | 0-100kHz | Control signal |
SF203-1 | 100VDC | 2x1A | 1 | 0-6MHz | Special fire alarm |
SF103-1 | 100VDC | 1x1A | 2 | 0-6MHz | Video signal |
SF-LAN100 | 250VAC | 3 | Network signal |
Note: Above signal filters are in compliance with standards specified by National Military Class C and D shielded room and anechoic chamber.
Please specify number of control line and current volume if control lines are more than 2 or current is bigger than 1A.